This inverter supports automatic export limiting when used with an AC power acquisition meter and current sensor. Installation and configuration: 1) Connect the RS485 cable from the AC power acquisition meter to the inverter's 485 port. 2) Insert the transmitted current sensor plug into the collector's "CT-IN" port (no + -). 3) Connect the collector's AC power input labeled "AC-IN" to the same AC supply that feeds your load; the collector will light up once powered. 4) On the inverter's LCD enter the battery-to-grid setting and enable the limiter by navigating to SET {Bat AutoLimit Grid} and selecting Y. 5) Follow the recommended power-up sequence: connect the inverter to AC power first, then attach the battery. Once configured, the inverter will output power equal to the value measured by the collector so no surplus energy is exported to the grid (automatic limiter function).