H100 VFD Vector Inverter Motor Speed Controller 0.75/1.5/2.2KW 110/220V 1PH→3PH 0–1000Hz with RS-485
Compact H100 VFD vector inverter available in 0.75KW, 1.5KW and 2.2KW versions. Designed for single-phase input and three-phase output, it supports both 110V and 220V input voltages and delivers an output frequency range of 0~1000Hz. Control methods include V/F and vector control, and the unit features RS-485 communication for integration and remote parameter setting. Parcel include: 1PCS 0.75kw/1.5kw/2.2kw VFD+1.5m extension cord Electrical & mechanical specifications (all variants share the same enclosure size): - Size: 89*149*110mm Variant-specific parameters: - 0.75KW (110): Input Voltage 110, Output Voltage 110, Input Frequency 50-60Hz, Output Frequency 0~1000Hz, Input Phase 1 phase, Output Phase 3 phase, Power 0.75KW - 1.5KW (110): Input Voltage 110, Output Voltage 110, Input Frequency 50-60Hz, Output Frequency 0~1000Hz, Input Phase 1 phase, Output Phase 3 phase, Power 1.5KW - 2.2KW (110): Input Voltage 110, Output Voltage 110, Input Frequency 50-60Hz, Output Frequency 0~1000Hz, Input Phase 1 phase, Output Phase 3 phase, Power 2.2KW - 0.75KW (220): Input Voltage 220, Output Voltage 220, Input Frequency 50-60Hz, Output Frequency 0~1000Hz, Input Phase 1 phase, Output Phase 3 phase, Power 0.75KW - 1.5KW (220): Input Voltage 220, Output Voltage 220, Input Frequency 50-60Hz, Output Frequency 0~1000Hz, Input Phase 1 phase, Output Phase 3 phase, Power 1.5KW - 2.2KW (220): Input Voltage 220, Output Voltage 220, Input Frequency 50-60Hz, Output Frequency 0~1000Hz, Input Phase 1 phase, Output Phase 3 phase, Power 2.2KW Key functions and advantages: - Multiple speed control options: V/F control and vector control modes (with RS-485 support) - Strong starting torque performance: Vector starting torque 0.5Hz up to 150% - Built-in 8-stage simple PLC function for multi-speed sequencing, plus PID control capability - Flexible frequency setup: digital setting, analog setting, PID setting and RS485 communication setting - Programmable I/O terminals allow custom combinations of working modes to match application needs - Jump frequency control to suppress mechanical resonance and improve system stability and reliability - Instantaneous power-down retention function to prevent production impact from brief power losses - Over torque and under torque detection for improved motor protection - Automatic voltage adjustment to address low-frequency oscillation issues in high-power motors - Comprehensive fault protection: over-current, over-voltage, under-voltage, over-heat, overload, lack of equal real-time monitoring and protection to ensure safe operation
Shipping & Returns
Shipping & Returns








