Wireless High And Low Voltage Current Ratio Tester ES1010
Tester High voltage detector Host (current clamp) Range 0.0mA~1200A(50/60Hz automatic) 0.0mA~20A Insolution 0.1mA 0.1mA Clamp Diameter φ50mm φ7.5mm Test Accuracy ±2%±5dgt ±0.5%±5dgt Sampling Speed 2 times/second Function:High-low voltage current transformer primary and secondary loop current, transformation ratio, polarity, phase, and on-line test; current and voltage ratio on both sides of transformer; on-line test; load current test Transmission type:Wireless transmission, straight line transmission distance 30m Shift gear:Automatic shift Power:DC6V 7# Alkaline battery(1.5V AAA×4) (Not included) DC7.5V 5 # Alkaline battery(1.5V LR6×5) (Not included) Test mode:Clamp CT Meter Dimension 87X37X262mm(W/T/H) Host::w100X35X204mm(W/T/H) Current clamp: 42X20X137mm(W/T/H) Display mode:LCD:128dots×64dots Blue screen backlight function, suitable for dark places LCD Size:62mm×44mm Ratio:Three kinds of transformation ratio display: (The primary and secondary circuit actually measured the current transformation ratio; the conversion ratio of the secondary circuit 5A; 10kV-YY transformer conversion ratio of 10kV/380V), the maximum ratio of 1:10 million Line voltage:Line test with insulation sheath below 60kV or bare wire current test below 35kV (must operate with insulation rod) Lead wire length:The lead wire of the current clamp 2 meter Weight:Total weight of instrument:3.1Kg(including insulation rob and instrument bag) High voltage detector:370g Host:409g Current clamp:180g Data interface:USB transmission Overflow display:Over-range overflow function: "OL A" symbol display Data storage:500 groups, press HOLD key to hold data, MR symbol display, press HOLD key to cancel hold Data review:Long press HOLD button to enter data review mode Data is full:Data full function: "FULL" symbol display No signal instruction:"NO SIGNAL -----" is displayed when the host does not receive the transmission signal Automatic shut-down:About 15 minutes after power on, the meter will automatically shut down Battery voltage:When the battery voltage drops to 5.2V, the low-power indicator lights to remind you to replace the battery:When the battery voltage drops to 5.2V, the battery voltage is low symbol to remind to replace the battery Insulated rod:Five section insulation rods (5 meters in total) Insulation strength:AC 60kV/rms Line test:Line test with insulation sheath below 60kV or bare wire current test below 35kV (operate with insulation rod) Working temperature:-10℃~40℃ Storage temperature:-10℃~60℃ Relative humidity:0℃~31℃≦75%,31℃~40℃≦50% Suitable for safety regulations:IEC1010-1、IEC1010-2-032、pollution level 2、CAT Ⅲ(600V) IEC61326(EMC standard)
Shipping & Returns
Shipping & Returns